Maytag • Model MVWC200XW2
Washer does not enter the spin cycle.
The shifter was found to transition into spin mode successfully, but the basket failed to spin. Testing indicated the shifter is functioning correctly, but the run capacitor was below specification.
The capacitor was replaced as it was found to have a measured capacitance of approximately 29 µF, which is below the required 45 µF.
Local proof: Austin · 78746 · Near Zilker Park